Air Operated Diaphragm Pumps

ARO
Click for Manufacturer Page

DIAPHRAGM SYSTEM ACCESSORIES

Before you order your diaphragm pump review your pump system requirements. Burt Process offers a full line of accessories to complete your pumping system installation.
635040
66073-1
66700X-XXX
SPECIFICATION:

Item Description

   Used With

Order Model

Aro-Stop Valve

   

Pump overrun control shuts off air to pump
when material container is empty or line is
broken. Quick set and reset feature included.

1/2” & 1” Pumps
1-1/2” & 2” Pumps

635040 

23644-400

Air Line Connection Kit

Kit includes Piggy back Filter/Regulator (Mini
Series for 1/2” and 1” pumps, Module Air 2000
for 1-1/2” and 2” pumps) with gauge, coupler,
connector, pipe nipple, and 5-foot section of
air hose.

1/2” & 1” Pumps

1-1/2” & 2” Pumps
3” Pumps

66073-1

66084-1

66109

Shock Blocker Pulsation Dampener

   

Patented dampener design permits either
manual or automatic pulsation dampening
with the same unit. Up to 97% pulsation
reduction can be achieved.

Any Style Pump
(100 psi max.)

66700X-XXX
Available in
polypropylene,

acetal, & PVDF

Cycle Counter Kit

   

Easy to install cycle counter records up to
999,999 cycles. Kit comes complete with
all necessary hardware for instant pump
installation. Excellent for fluid inventory,
preventive maintenance, and fluid metering.

1/2”, 1”, 1-1/2”

& 2” Pumps

66975


 
PNEUMATICALLY CONTROLLED LIQUID LEVEL SENSORS
For more information request bulletin 9112-M
Model 59916-1

These liquid level sensors are designed to produce a pneumatic output signal as the fluid level in an unpressurized vessel rises or falls past a predetermined level. The will accurately sense almost any fluid.


Models 59916-1 and -2 are identical except that their function is reversed.


Model 59916-1 will produce an output signal when sensing tube is blocked by a liquid. Model 59916-2 will produce an output signal when the sensing tube is not blocked by a liquid. The output signal generated at the “Signal out port,” will be a three-way type signal in both cases.


When on, the output signal will be of the same pressure as that supplied to the port marked (AIR INLET). When off, the output will be connected to atmosphere through an exhaust port within the enclosure. This insures a quick and sharp on-off signal from the sensor package.


The supply pressure to the sensor can be any pressure between 30 and 150 psig. However, where possible, pressures between 50 and 100 psig are recommended for quickest response and maximum life.
Burt Process offers a complete line of liquid level sensors. Refer to pages 106-117.