Flow Control Valves
PLAST-O-MATIC
Click for Manufacturer Page
SERIES "TUC" SOLENOID DIAPGRAGM DIVERTER VALVES    
    SPECIFICATIONS
 
Double diaphragm valves for highly corrosive or ultra-pure liquids. In-line flow pattern. Orifice diameters of 3/32”, 1/8” and 1/4” with inlet pressures of 50, 25 and 18 PSI respectively. Available in electric or pneumatic operation.
Ordering PVC specify 4044-(Part No.)
Ordering Polypropylene specify 4045-(Part No.)
Ordering Teflon specify 4046-(Part No.)
Ordering PVDF specify 4047- (Part No.)
 
Pipe Size Orifice Size PVC Polypropylene
Model No. Model No.
1/4" 1/8" TUC2V4W20-PV TUC2V4W20-PP
1/2" 1/8" TUC4V4W20-PV TUC4V4W20-PP
1/4" 1/4" TUC2V8W20-PV TUC2V8W20-PP
1/2" 1/4" TUC4V8W20-PV TUC4V8W20-PP
Above prices for Viton Seals & 20 Watt Coils. Buna-N Seals & D.C. Coils available. Also available in Teflon & PVDF.

    SERIES "TUCA" DIVERTER VALVES
SPECIFICATIONS  
Double diaphragm valves for highly corrosive or ultra-pure liquids. In-line flow pattern. Orifice diameters of 3/32”, 1/8” and 1/4” with inlet pressures of 50, 25 and 18 PSI respectively. Available in electric or pneumatic operation.  
Pipe Size Valve Saels PVC Polypropylene
Model No. Model No.
1/4" Buna-N TUCA025B-PV TUCA025B-PP
1/4" Viton TUCA025V-PV TUCA025V-PP
1/2" Buna-N TUCA050B-PV TUCA050B-PP
1/2" Viton TUCA050V-PV TUCA050V-PP
 

SERIES "F" AUTOMATIC DIVERTER VALVES AIR OPERATED   SPECIFICATIONS
  Air-operated diverter valves divert flow from one common inlet to two separate outlets, or from two inlets to one common outlet,. No metal contact with controlled liquid. Sizes 1/2” to 2” NPT.
 
Pipe Size Valve Saels PVC
Model No.
3/4" Buna-N F075B-PV
3/4" Viton F075V-PV
1" Buna-N F0100B-PV
1" Viton F0100V-PV
1-1/4" Buna-N F0125B-PV
1-1/4" Viton F0125V-PV
1-1/2" Buna-N F0150B-PV
1-1/2" Viton F0150V-PV
2" Buna-N F0200B-PV
2" Viton F0200V-PV

SERIES "EST" AUTOMATIC SHUTOFF VALVES AIR OPERATED  
Normally closed, normally open, air by air, line pressure by air pressure operation. FAIL-DRY design. Bubble-tight shutoff. Visual valve position. In-line flow patterns. Sizes 1/2” to 2” NPT.  
 
SPECIFICATIONS
Pipe Size Normally Closed Normally Open
Model No. Model No.
3/4" EST075V-NC-PV EST075V-NO-PV
1" EST100V-NC-PV EST100V-NO-PV
1-1/4" EST125V-NC-PV EST125V-NO-PV
1-1/2" EST150V-NC-PV EST150V-NO-PV
2" EST200V-NC-PV EST200V-NO-PV
Above prices for Viton Seals. Buna-N Seals available upon request.